Technical Data Designed to be used as part of an ultra high speed floor maintance system in: ! Hospitals, nursing homes, doctors offices ! Schools, universities, child care centers ! Supermarkets, malls, retail stores Specifications Available Sizes ....................... 4/1G, 5G, 55G Physical State ..................................... Liquid Color ........................................ Milky White Fragrance .......................................... Acrylic Total solids ............................................ 21% Metal Interlocked ..................................... Yes Initial Gloss .................................. Very High Leveling .......................................... Excellent Scuff Resistance .................................... High Burnisher Response .................... Outstanding Specific Gravity ................................... 1.029 pH .......................................................... 9.0 What the Pros Know Don’t apply if floor surface temperature is less than 45°F. Powdering will result. Allow extra curing time in humid conditions. Rushing coats will cause recoat disturbance and dulling. Don’t overwork finish - just spread evenly and allow to dry. Apply finish only with a clean finish mop - never use a cleaning mop. See label for complete directions and use only as directed. MIRAQUEST PLUS exceeds the minimum slip resistance requirements for floor finishes when tested in accordance with ASTM 2047-82 (UL test procedure). ! High solids - Requires fewer coats ! Latest polymer technology - Durable wet look gloss ! Designed for high traffic - Unequaled gloss and scuff resistance ! Unique polymer system - Easy to apply, repair, and re-coat ! Tough film - Compatible with UHS electric, battery, and propane equipment ! Removes with emulsifying strippers - Easy to remove The latest floor care polymer technology is used to create a product that delivers wet-look gloss and outstanding durability. The unique polymer system provides ease of use and even application onto resilient flooring or most non-resilient surfaces. The finish resists scuffs, abrasions, black heel marks and offers outstanding chemical resistance. The ideal foundation for an UHS floor maintenance system. Following a planned maintenance schedule will prolong the life of your finish. Extending the life of your finish extends the time between required "scrub & recoats" and "strip-outs", resulting in a reduction of overall labor cost. Wear safety equipment recommended on MSDS, place Wet Floor Signs and read all directions and cautions prior to beginning your work. Thoroughly strip or clean floor and allow to dry prior to application. Stripping all old coatings is recommended prior to initial application. Apply this product in a uniform, medium coat. Allow each coat to dry to the touch prior to applying additional coats. Three to five coats are recommended for initial application (2 to 3 coats when used over a seal). Restore gloss by applying Meteor UHS Restorer or occasional dry burnishing (use 1500+ RPM equipment). Consult your Triple S representative for proper pad selection. CS-840 6/01 MATERIAL SAFETY DATA SHEET ....... ................. ............................. .............. .................... .............. SECTION 1 -PRODUCT ..... .............. .................... ................... ............. ............ SECTION 2 -HAZARDOUS INGREDIENTS SECTION 3 -HEALTH HAZARD & FIRST AID .. ................... .... .. ...................... .... .. .......... .. .. ..................... .. ................................................................... ....................................... .. .......................... .. .................................... ............. .. ............................................................... ...................... .. ................................................................... ................................................................... ............................................. ...................................................................... .................. .................. SECTION 4 -PHYSICAL & CHEMICAL CHARACTERISTICS ................. ...... ........ ........... ....... ....... ...................... ............ ............................. ..... ..... ... ................. ... .............. .................... ................. ... SECTION 5 -FIRE AND EXPLOSION HAZARD .............. .................... ...................... ... ................................... ... .................................. ..... ......... ....... ........ ... .............................................................. SECTION 6 -REACTIVITY DATA ............ ...... ...................... .......... SECTION 7 -SPILL OR LEAK PROCEDURES .. .................................................................... ............... .................................................. SECTION 8 -PERSONAL PROTECTION ................ SECTION 9 -SPECIAL PRECAUTIONS .............................................................. ...................................... SECTION 10 -SECTION 313 SUPPLIER NOTIFICATION (SARA) ............................................................................ ................................................................... ............................................ ............................. ............ ........ ....................... .............. ........ SECTION 11 -TOXICOLOGICAL INFORMATION SECTION 12 -ECOLOGICAL INFORMATION SECTION 13 -DISPOSAL CONSIDERATIONS ....................... SECTION 14 -DOT TRANSPORT INFORMATION ................................. SECTION 15 -OTHER REGULATORY INFORMATION .................................................. SECTION 16 -OTHER INFORMATION ....................... .................................. ......................................................................... ........................................................................... ..................................................................... ....................................................................... ........................................................................